Skip to Content

Lighting requirements for the Industrial Sector

13 de gener de 2026 per
Lighting requirements for the Industrial Sector
AUSSIE GROUP S.L., Marc Feliu

In the context of modern industry, proper lighting is not just a matter of visibility, but a strategic tool to enhance safety, energy efficiency, and productivity.

Well-balanced lighting levels are essential for establishing safe and productive working conditions. Companies must take into account the lighting in the workplace where industrial activities are carried out. The optimization of industrial lighting must consider the work activity, environmental conditions, and energy expenditure. Proper lighting leads to greater productivity and accuracy, safety, protection, and a better environment for workers.

A poor choice in lighting systems can lead to accidents, low work performance, or even legal non-compliance. Therefore, understanding the lighting requirements for the industrial sector and being aware of the current lighting regulations is essential for architects, construction companies, and professionals responsible for designing efficient and safe industrial spaces.


Main lighting regulations in industries

Regulation

Application

Summary

UNE-EN 12464-1:2012

Interiors

Establishes minimum lighting levels in industrial work areas.

UNE-EN 12464-2:2016

Exteriors

Lighting requirements in docks, parking lots, roadways, etc.

REBT (Low Voltage Electrotechnical Regulation)

Electrical installations

Regulates safety in electrical lighting installations.

CTE (Technical Building Code)

Industrial buildings

Includes criteria for energy efficiency and lighting integration.

RD 1890/2008

Outdoor lighting

Regulations on energy efficiency and light pollution.

NTP 1.076 (no obligatoria)

Loading docks

Technical guide with specific lighting recommendations.


What does the industrial lighting regulation cover?

The lighting regulations establish the minimum conditions that a lighting system must meet in work environments. This regulates aspects such as:

  • ·         La iluminancia mínima (lux) según tipo de tarea.
  • ·         La uniformidad de la luz (Uo) y el control del deslumbramiento (UGR).
  • ·         La reproducción cromática (CRI), crucial para tareas de precisión.
  • ·         Requisitos técnicos y de eficiencia energética para interiores y exteriores.
  • These regulations not only improve the well-being and safety of workers, but also ensure that the facilities are sustainable, in accordance with the current legal framework.

Industrial Zone

Minimum Illuminance

Uniformity (Uo)

UGR

CRI / Ra

Production (general tasks)

200 – 300 lx

≥ 0.6

≤ 25

≥ 80

Production (fine tasks)

Hasta 1500 lx

≥ 0.7

≤ 19

≥ 90

Drying areas or low demand

50 lx

≥ 0.4

≤ 25

≥ 60

Warehouses of goods

≥ 150 lx

≥ 0.4

≤ 22

≥ 60

Shipping areas

300 lx

≥ 0.6

≤ 25

≥ 60

Loading and unloading docks

100 lx

≥ 0.4

≤ 25

≥ 60

Outdoor parking

10 – 50 lx

≥ 0.4

≤ 25

≥ 60

Outdoor industrial roads

≥ 20 lx

≥ 0.4

≤ 25

≥ 60

Key recommendations for industrial lighting

The industrial lighting standards address the importance of evaluating energy consumption and other key features aimed at improving overall performance in the workplace.

Zoning and adaptability

A proper design enhances safety, prevents errors, and optimizes consumption. Each area should have its own level of lighting according to the type of task:

  • Production areas: Require between 200–1500 lux depending on the precision.​
  • Warehouses: Minimum illuminance of 150 lux, with linear or asymmetric optics​.
  • Docks and exteriors: Minimum 100 lux according to NTP recommendations.

Use of LED lighting and smart control

Choosing industrial LED technology ensures energy efficiency, low maintenance, and a lifespan of over 50,000 hours. It is recommended to incorporate:

  • DALI systems for regulation.
  • Presence or natural light sensors.
  • Wireless communication (ZigBee) in hard-to-reach areas.

Regulations and technical quality

The luminaires must have:

  • IP65 protection (dust and water).
  • Impact resistance IK08.
  • Low UGR to avoid visual fatigue.​
  • High color rendering (CRI ≥ 80).

Regulatory and Technical Summary

This regulatory and technical compendium is present in the development of all Luxes systems for all types of industrial spaces. From the definition of the color spectrum to the selection of each lamp, everything is designed to provide a precise visual experience, without shadows, and energy-efficient.

NTP 1076: Muelles de carga y descarga: seguridad | INSST - PDF - Portal INSST - INSST. (s. f.). Portal INSST.
 https://www.insst.es/documentacion/colecciones-tecnicas/ntp-notas-tecnicas-de-prevencion/31-serie-ntp-numeros-1066-a-1101-ano-2016/ntp-1.076-muelles-de-carga-y-descarga-seguridad
NTP 211: Iluminación de los centros de trabajo - PDF - Portal INSST - INSST. (s. f.-b). Portal INSST.
 https://www.insst.es/documentacion/colecciones-tecnicas/ntp-notas-tecnicas-de-prevencion/6-serie-ntp-numeros-191-a-225-ano-1989/ntp-211-iluminacion-de-los-centros-de-trabajo
UNE-EN 12464-1:2022 Luz e iluminación. Iluminación de los luga. . . (s. f.).
https://www.une.org/encuentra-tu-norma/busca-tu-norma/norma?c=N0068596

Other related projects

Su fragmento dinámico aparecerá aquí... Este mensaje aparece porque no proporcionó ni el filtro ni la plantilla a usar.